BWRPJ - TITANIUM DIOXIDE P-25
- MSDS: BWRPJ
- Manufacturer: DEGUSSA CORP
- Product Name: TITANIUM DIOXIDE P-25
- National Stock Number: 6810-00N057044
Product Identification
Product ID:TITANIUM DIOXIDE P-25
MSDS Date:01/20/1994
FSC:6810
NIIN:00N057044
MSDS Number: BWRPJ
Responsible Party
RIDGEFIELD, NJ 07660
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 201-641-6100
Cage: 8C791
Contractor
Telephone: 201-818-3706
Cage: 8C791
Ingredients
TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: >99.5%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
Hazards
LD50 LC50 Mixture:LD50 (ORAL,RAT): >10,000 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: MAY CAUSE DISCOMFORT. SKIN: MAY
CAUSE DRYING OF SKIN. SKIN ABSORPTION: NOT EXPECTED TO BE ABSORBED
THROUGH SKIN. INHALATION: MAY CAUSE PHYSICAL DISCOMFORT TO
RESPIRATORY TRACT. INGESTION: NOT EXP ECTED TO BE TOXIC BY
INGESTION.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:CONJUNCTIVITIS OF EYE, DERMATITIS
OF SKIN, ASTHMA AND RESPIRATORY DISEASES.
First Aid
First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. CALL PHYSICIAN
IF DISCOMFORT PERSISTS. SKIN: WASH WITH SOAP AND WATER. CALL
PHYSICIAN IF DRYING PERSISTS. SKIN ABSORPTION: FLUSH WITH SOAP AND
WATER. INH ALATION: REMOVE TO FRESH AIR. IF DISCOMFORT PERSISTS,
CALL PHYSICIAN. INGESTION: CALL MD IMMEDIATELY .
Fire Fighting
Flash Point:NON-FLAMMABLE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . EVACUATE ENCLOSED AND SURROUNDING AREAS.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:FOR SMALL SPILLS, SWEEP OR SHOVEL SOLIDS INTO
PROPER CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN COOL, DRY, WELL-VENTILATED
AREA AWAY FROM SOURCES OF IGNITION. KEEP CONTAINERS TIGHTLY CLOSED
WHEN NOT IN USE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:ATMOSPHERIC LEVELS SHOULD BE MAINTAINED BELOW
EXPOSURE LIMITS LISTED BY USING ENGINEERING CONTROLS. IF NOT
FEASIBLE, USE A NIOSH/MSHA APPROVED AIR-PURIFYING RESPIRATOR WITH
APPROVED FILTERS AND/OR SOR BENTS.
Ventilation:PROVIDE GEN &/OR LOC EXHST VENT TO MAINTAIN AIRBORNE LEVS
BELOW EXPOS LIMITS.REFER TO "INDUSTRIAL VENT" BY ACGIH(SUPDAT)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGG .
Other Protective Equipment:LOTIONS & BARRIER CREAMS ARE ALSO RECOM TO
PVNT DRYING OF SKIN.IF RPTD/PRLNGD SKIN CONT/CONTAM IS LIKELY, PROT
(SUPDAT)
Work Hygienic Practices:ESTABLISH GOOD PERSONAL HYGIENE AND WORK
PRACTICES. ALWAYS WASH HANDS AND FACE BEFORE EATING, DRINKING OR
SMOKING.
Supplemental Safety and Health
PH: 3.0-4.0. VENTILATION: FOR MANUAL OF RECOMMENDED PRACTICES. OTHER
PROTECTIVE EQUIPMENT: CLOTHING SHOULD BE WORN.
Chemical Properties
HCC:C3
Melt/Freeze Pt:M.P/F.P Text:3362F,1850C
Spec Gravity:3.8
pH:SUPDAT
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE POWDER WITH NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE KNOWN.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS. CONTACT DEGUSSA AT (205) 443-4000, EXT.
2287 OR EXT. 2427 FOR ASSISTANCE WITH DISPOSAL REQUIREMENTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.